The Bead Ruptor Elite: Prep Smarter.
High-Throughput Science Starts Here
Whether you're working with the toughest samples, or a variety of sample sizes, the Bead Ruptor ELITE quickly and easily delivers.

WHAT THEY'RE SAYING:

Elite User
“Drastically increased efficiency and decreased turnaround times”
Automate Sample Prep and Improve Data Reproducibility Without Compromising Sample Integrity
The Bead Ruptor Elite is a high-performance bead mill homogenizer engineered for high-throughput, automated homogenization of tough tissue, plant, and microbial samples.
Ideal for labs requiring reproducible results, the Elite homogenizer streamlines workflows and delivers consistent performance across a wide range of biological and clinical applications.
Its unique sealed, inclined carriage system enables rapid, uniform sample disruption with minimal heat generation—preserving the integrity of sensitive biomolecules such as RNA, DNA, and proteins.
- Processing range: 25 µL to 50 mL
- Run Time: 1 second to 9:59 minutes
- Performance range: 0.8 – 8 m/s in increments of 0.15 m/s
- Number of Cycles: 1-10
- Safety: integrated lid lock to prevent lid opening during operation
- Waterproof seal
- Dimensions: W: 15” (38.1 cm), D: 17” (43.2 cm), H: 13” (33.0 cm)
- No cool down
- Unlimited protocols
- Touchscreen with user defined programs, tube configuration and parameter control
- Power rating: 115-230 VAC, 50/60 Hz
- Product weight: 65 lbs. (29 kg)
- Warranty: one year
- Standards approval: TUV, CE and UKCA approved
Your Workflow Wins on Day 1
Process up to 48 samples in one run without stopping—perfect for high-throughput screens, biomarker panels, or multi-tissue studies that demand speed without sacrificing control.
Get consistent RNA, DNA, and protein yields across every batch—thanks to uniform mechanical lysis that eliminates the variability of manual or enzyme-based methods.
Run confidently with validation across NGS, LC-MS, and biomarker assays—trusted by top labs for everything from pharmacogenomics to microbiome profiling and proteomic discovery.

Engineered for Scientists Who Demand Speed, Consistency, and Integrity
The Bead Ruptor Elite delivers unmatched throughput, uniform disruption, and heat-controlled homogenization—designed to eliminate bottlenecks and protect what matters most: your data.
Specs at a Glance:
Top Bead Ruptor Elite Use Cases & App Notes
NGS & Genomic Sequencing
High-throughput NGS starts with consistent nucleic acid extraction. The Elite’s mechanical lysis avoids heat and enzymatic degradation, delivering high-purity DNA and RNA—essential for reproducible read depth and clean variant calling.
RNA Expression Analysis
In-depth analysis of RNA expression begins with sample lysis. Since RNA is a fragile biomolecule, attention must be paid when selecting a lysis protocol that doesn’t destroy the RNA before it gets analyzed. Elite brings just the right amount of power and reliability to lyse tissue samples without harming delicate RNA analytes.
LC-MS & Metabolite Analysis
In small-molecule workflows, variability at the sample prep stage can throw off quantitation. Elite enables uniform disruption across biological matrices like tissue, plasma, and umbilical cord—so your downstream data reflects biology, not prep inconsistencies.
Biomarker Discovery
When detecting subtle shifts in protein or RNA expression, even small prep inconsistencies can create false signals. Elite minimizes variability and protects fragile molecules, giving you higher-confidence hits from your panels.
Microbiome & 16S Sequencing
Some bacteria are tough to lyse—especially in stool, soil, or environmental samples. Elite’s high-G-force bead milling ensures complete disruption, unlocking accurate microbial profiling and reducing bias toward easier-to-lyse species.
FEATURED WEBINAR
BioLegend's Approach To Quantifying Immune Mediators From Tissue
Get an inside look at an efficient tissue lysate preparation workflow using the Omni Bead Ruptor Elite™ and simultaneous quantification of 13 cytokine release syndrome (CRS) biomarkers using BioLegend's LEGENDplex™ Cytokine Release Syndrome panel, advancing the understanding of CRS and supporting the development of targeted immunotherapies.
Transparent Pricing, Tangible ROI—Because Every Dollar Counts
You shouldn't have to guess whether automation will pay off. With the Bead Ruptor Elite, it’s not just about power—it’s about value.
Use our ROI calculator to see how quickly the Elite pays for itself through time saved, reduced rework, and lower per-sample labor. Its maintenance-free motor keeps operating costs low, while durable, continuous-use design means fewer disruptions and no costly service contracts.
For academic and government labs, the Elite may be eligible for Shared Instrumentation Grants, making it easier to secure external funding and bring advanced automation to your core or department.
HEAD-TO-HEAD COMPARISON
Manual Sample Prep vs Bead Ruptor Elite
Typical Time Savings in Preparing 24 Samples
The comparison was created using soft and hard tissue types commonly used in biological research, including mouse liver, skeletal muscle, kidney, lung, heart, and spleen, as well as MCF7 cultured cells. Homogenization times for the Bead Ruptor Elite were calculated using data from five recent application notes published by Omni R&D. All application notes used 2 mL tubes and followed standard tissue lysis protocols.
Manual preparation, in the context of this comparison, is based on protocols using a mortar and pestle to lyse tissue—an approach that introduces significant variability and requires hands-on time for each sample. All pipetting steps were considered using a single-channel pipette.
Sample Processing Step | Time it Takes to Manually Prep (in min) | Time It Takes Using LH 96 (in min) |
---|---|---|
Sample Weighing | 720 | 650 |
Buffer Addition, Homogenization, Sample Reformatting | 576 | 335 |
Average Time Spent Cleaning Stainless Steel (SS) Probes Used in Manual Method1 | 19202 | – |
Total Time Preparing and Cleaning | 3216 | 985 |
Sample Processing Step
Low-End Manual Prep (min)
Low-End Bead Ruptor Elite
(min)
High-End Manual Prep (min)
High-End Bead Ruptor Elite
(min)
Sample Cutting
48
48
48
48
Buffer and Sample Addition
4
4
4
4
Homogenization*
48
0.67
240
2.5
Total Time Preparing
100
53
292
55
Sample Processing Step
Time to Manually Prep
(in min)
Time It Takes Using LH 96
(in min)
Sample Weighing
720
650
Buffer Addition, Homogenization, Sample Reformatting
576
335
Average Time Spent Cleaning Stainless Steel (SS) Probes Used in Manual Method1
19202
–
Total Time Preparing and Cleaning
3216
985

237
MINUTES SAVED PER 24 SAMPLES COMPARED TO HIGH-END MANUAL PREP
81%
TIME SAVINGS USING BEAD RUPTOR ELITE VS MANUAL (HIGH-END)
5x
MORE BATCHES PER DAY WITH BEAD RUPTOR ELITE
*Homogenization step for manual methods only include the time spent manually lysing the sample using mortar and pestle. This time does not include additional lysis buffer incubations that typically follow and can add up to 45 minutes to the protocol depending on tissue type. Similarly, homogenization step for Omni methods includes time spent homogenizing the sample on the Bead Ruptor Elite. Both manual and Omni methods do not include time spent post-lysis centrifuging the samples.
Sample Weighing
Time It Takes to Manually Prep
720 minutes
Time It Takes Using LH 96
650 minutes
Manual preparation, in the context of this comparison, is defined as using a handheld motorized tissue homogenizer to individually homogenize 1 sample at a time for a 45-second cycle. All pipetting/reformatting steps were considered using a single-channel pipette.
Note: stainless steel probes are typically used when manually creating tissue lysates using a motorized tissue homogenizer. Time spent cleaning these probes in-between samples can range depending on cleaning method from as little as 5 minutes to wipe down and clean probe vs. 1 hour to autoclave the probe.
The Industry's Only User-Centered Design + Engineering
Features | BR Elite | Competitor 1 | Competitor 2 | Competitor 3 |
---|---|---|---|---|
Unique inclined carriage motion designed to maximize lysis efficiency | ||||
Engineered for highest sample yield and quality | ||||
Broadest G-Force for precision tuning of homogenization | ||||
Accommodates different samples and size within single device | ||||
User-Centric inclined carriage for ease of use | ||||
No cool down time between sample runs | ||||
Integrated transparent locking lid for improved safety and access | ||||
Industrial, no-maintenance build for lowest total cost of ownership | ||||
Broadest tube size compatibility for unparalleled flexibility in sample size | ||||
Near silent operation (<72dB) minimizing noise |
Labs That Trust Elite









5.0 RATING
“Powerful homogenization in a small footprint. A must-have for every laboratory.”
Application Area: Trace residue analysis in crop and environmental samples.
"Our Bead Ruptor has been an enormous time saver. Previously sample homogenization of multiple samples could be a bottleneck. Especially if multiple chemists needed to use our traditional homogenizers, which are expensive and take up a lot of bench space. The Bead Ruptor makes quick work of multiple samples at once."
– Steven Perez
ADPEN Laboratories, Inc.

5.0 RATING
Application Area: Analyzing pig veins and arteries for various compounds.
“For years, I was analyzing pig veins and arteries for various compounds. I was manually homogenizing them in a variety of diluents using a handheld homogenizer with a stainless steel tip. This was a very labor-intensive process that required the use of glass vials. With the OMNI Bead Ruptor, I was able to transfer the sample tissue to a bead ruptor tube with ceramic beads and homogenize multiple samples simultaneously. This drastically increased efficiency in the laboratory and decreased turnaround times for our clients.”
– Chad Dean
Senior Research Scientist, Laboratory
Services, Bioanalytical Lab
PPD Early Preclinical Research
Thermo Fisher Scientific

5.0 RATING
“It is easier to use, safer (no solvent splashes), and quieter (no hearing protection required)”
Application Area: Homogenize animal tissues in organic solvents.
"We purchased this product to replace a traditional shearing homogenizer. It is easier to use, safer (no solvent splashes), and quieter (no hearing protection required). It is programmable, ensuring consistent handling of all samples. It processes up to 24 samples simultaneously. It is very powerful. We process most of our samples for two to three cycles at 10 to 15 seconds per cycle."
– Bonne Thompson
UT Southwestern Med Ctr
ABOUT OMNI
Commitment to Support
At Omni, we don’t just sell products and disappear.
We pride ourselves on providing unrivaled customer support—our relationship with you goes far beyond the purchase. Our team of dedicated scientists and engineers works closely with you to ensure that your LH 96 is fully customized for your unique workflows.
From setup to troubleshooting, we offer personalized assistance every step of the way, ensuring seamless integration and maximum performance.
Unlike others in the industry, Omni’s support is proactive and ongoing, with experts readily available to provide real-time solutions and tailored guidance. When you choose Omni, you’re not just buying a product—you’re gaining a partner who’s as invested in your lab’s success as you are.
Ready to Purchase?
By Phone
Please call 770-421-0058 to place your order directly with us.
By Online Purchase
You will be directed to our parent company Revvity's website to complete your purchase.